AAA Solar Simulator
Application:
The Solar Panel IV Tester is designed for automatic electrical performance testing and data recording of monocrystalline, polycrystalline, and thin-film solar modules. It uses simulated sunlight to test PV modules and evaluate their electrical performance, helping manufacturers inspect solar panel quality and verify module output during production.
Key Features of the Solar Panel IV Tester
-
Adjustable Flash Duration: Continuously adjustable flash duration from 0–60 ms, with 100 ms available as a customized option.
-
High-Speed Data Acquisition: Four-wire measurement system equipped with a 14-bit, 4-channel high-speed synchronous data acquisition card, supporting up to 8,000 data sampling points.
-
10-Parameter Display: Displays 10 measurement parameters in both tabular and graphical formats for clear and convenient test result analysis.
-
Automatic Compensation: Automatic irradiance compensation and temperature compensation to improve measurement accuracy.
-
Voice Counting and Flash-Time Alerts: Voice announcements for counting and reminders of the flash count.
-
Continuous Operation and Xenon Lamp Life: Supports 24-hour continuous operation. The imported xenon lamp has a service life of up to 300,000 flashes.
-
Patented Design and Quality Components: Features a patented design and high-quality key components for reliable equipment performance.
-
Touchscreen Operation: Equipped with a touchscreen control system for convenient operation and parameter settings.
-
Independent Explosion-Proof Control Cabinet: Features an independent explosion-proof electrical control cabinet.
Technical Data:
|
Model
|
YHPT-AAA
|
Feature
|
|
Lamp Spectrum
|
In line with IEC60904-9:2007(A Grade)
|
1. Measurable parameters: I-V curve, short circuit current, open circuit voltage, peak power, peak power point voltage, current, fixed voltage current, filling factor, conversion efficiency, light intensity and environmental temperature.
2. Automatic classification and display function. It can be automatically classified according to the fixed voltage and current, and the results of the classification can be displayed directly on the test cabinet by digital display. Easy to use in production line.
3. Solar cells are connected by four wires to ensure the current accuracy.
4. Measuring temperature and light intensity at the same time to ensure the accuracy of automatic correction of solar cell temperature and light intensity.
5. Self-tuning system with manual input compensation parameters, automatic/manual temperature compensation, automatic light intensity compensation, etc.
|
|
Light Intensity
|
1000W/m²(700W/m²-1200W/m²)
|
|
Light intensity non-uniformity
|
≤±2%[AAA]
|
|
Instability degree of irradiation
|
≤±1%[AAA]
|
|
Test results consistency
|
≤±0.05%[AAA]
|
|
Test error of electrical properties
|
≤1% AAA
|
|
Single flash time
|
60ms 100ms 150ms(Optional)
|
|
Effective Test Range
|
2500mm×1400mm
2600*1500mm(Optional)
|
|
Measuring Voltage
|
0-200V(Resolution 1mV)
|
|
Measuring current
|
200mA-20A(Resolution 1mA)
|
|
Environmental temperature
|
15℃~30℃
|
|
Test Parameters
|
Isc, Voc,Pmax, Vm,Im,FF,EFF,Temp,Rs,Rsh
|
|
power
|
220V/50Hz(60Hz)
|
Equipment, machine configuration:
1. Test Host(With electronic load):1 set
2. Light source(With optical system):2 Pieces
3. PC:1 set
4. High-speed data collection A/D plant:1 piece
5. Dedicated measurement software:1 set
6. Test bench:1 set
7. Standard Battery(Compensation and correction for the irradiance uniformity measurements):1 piece
8. Size:2.64*1.48*1.2m (Host)+0.86*0.61*0.95m(Spare parts)
9. G.weight:400KGS+25KGS
Key Components:
|
SN
|
Name
|
Brand
|
Qty
|
|
1
|
Test Host(With electronic load)
|
Customized
|
1
|
|
2
|
High-speed data collection A/D Card
|
Customized
|
1
|
|
3
|
PLC
|
Siemens PLC
|
1
|
|
4
|
Touch-screen control
|
TK6070IH
|
1
|
|
6
|
Light source
|
Germany Haimam
|
2
|
|
7
|
Computer
|
Industrial computer
|
1
|
Environmental requirements:
Indoor light intensity < 100cd
Indoor ambient temperature: 20 + 6 degrees
Extreme outdoor maximum temperature 40.0 degrees
Extreme Minimum Outdoor Temperature - 25.1 Degree
Relative humidity 40%
Elevation 923M
Summer atmospheric pressure 890.9 mbar
Winter atmospheric pressure 903.5mbar
Power supply: It should conform to China's electrical specifications.
Voltage: 380V and 220V Frequency: 50Hz
All electrical equipment shall be suitable for the following operating conditions and shall not affect its performance.
Voltage fluctuations: 380V (+10%) and 220V (+10%)
Frequency fluctuation: 50 Hz +2%
Grounding resistance: <0.5
Distribution cabinet over 1.5 meters