Solar Simulator for PV Module Testing
Application:
Used for the automatic testing and recording of electrical performance parameters of monocrystalline and polycrystalline silicon solar modules during photovoltaic (PV) module manufacturing and quality inspection.
Products Features:
1. Customized Load Board Compatibility
The customized load board is compatible with various solar cell technologies, including PERC, TOPCon, HJT, SUNPOWER, and IBC. It supports MBB (Multi-Busbar), half-cut cells, stacked cells, and thin-film solar modules, with corresponding electrical performance parameter testing capabilities.
2. High-Efficiency Direct-Light Structure
Featuring a high-efficiency direct-light structure, the equipment simulates real solar irradiation conditions. Depending on the on-site environment, it supports both side-lighting and top-lighting installation configurations.
The full spectral range covers 300–1200 nm, with an adjustable pulse width ranging from 10 ms to 150 ms.
3. Industry-Leading Spectral Performance
The equipment meets advanced industry spectral performance standards:
1. A+A+A+ Performance
The three core performance indicators—irradiance non-uniformity, spectral match, and irradiance stability—all exceed industry standards.
2. Full-Spectrum Testing
With a spectral range of 300–1200 nm, the equipment supports full-spectrum testing of high-efficiency silicon solar cells, significantly improving testing accuracy.
3. Four-Wire Connection and High-Speed Data Acquisition
Equipped with a four-wire connection system and high-speed data acquisition system, the equipment ensures accurate solar cell current measurement.
4. Infrared Non-Contact Temperature Measurement
The infrared non-contact temperature measurement system accurately measures solar module temperatures, ensuring the accuracy of temperature correction.
Main technical and principles of the equipment:
|
Category
|
Specification
|
Details
|
|
Analog Light Source
|
Spectral Matching
|
100 mW/cm²
|
|
Total Irradiation Intensity
|
70 mW/cm² to 120 mW/cm²
|
|
Range of Irradiance Adjustment
|
± 1%
|
|
Irradiation Unevenness
|
± 1%
|
|
Single Irradiation Pulse Time
|
10-150 ms (adjustable)
|
|
Flash Count Prompt Function
|
Flash count prompt (replacement, reset to zero)
|
|
Xenon Lamp Service Life
|
80,000 flashes
|
|
Radiation Direction
|
Vertically downward light emission
|
|
Measurement Range
|
Effective Testing Area
|
2600 mm x 1600 mm
|
|
Effective Testing Range
|
5 W to 650 W (maximum component area power)
|
|
Measurement Voltage
|
0 mV to 200 V (resolution of 1 mV)
|
|
Measuring Current
|
0 mA to 20 A (resolution of 1 mA)
|
|
Environmental Temperature
|
15°C to 35°C
|
|
Measurement Accuracy
|
Inconsistency of Measurement Results
|
± 0.5%
|
|
Measurement Result Error
|
± 1%
|
|
Measurement Method
|
Measurement Method
|
Four-line measurement
|
|
Measurement Parameters
|
Parameters
|
Isc, Voc, Pmax, Vm, Im, FF, EFF, Temperature, Rs, Rsh
|
|
Measurement Interval Time
|
Interval
|
<20s (100ms pulse), <30s (150ms pulse)
|
|
Data Collection
|
Data Points
|
8,000 data points for I-V and P-V curves
|
|
Test Condition Correction
|
Automatic Irradiance Compensation
|
Yes
|
|
Automatic Temperature Compensation
|
Yes
|
|
Temperature Measurement
|
Temperature Compensation and Display
|
Yes
|
|
Built-in Non-contact Infrared Temperature Measurement
|
Yes
|
|
Test Results
|
Voice Counting and Prompts
|
Yes
|
|
Display Test Time and Graphical Parameters
|
I-V characteristic curve
|
|
Test Report
|
Current Work Interface
|
Displays and records I-V characteristic curves
|
|
Save Test Parameters
|
Can save the main test parameters of all components to a specified file on the hard drive
|
|
Autonomous Naming of Files
|
Yes
|
|
Data Summary and Printing
|
Summarize Data
|
According to the set time period or at any time
|
|
Print Format
|
Excel format (including cumulative output of I-V characteristic curves)
|
|
Specialized Software
|
Temperature Compensation Coefficient Input
|
Yes
|
|
Date Name Rows and Counts Input
|
Yes
|
|
Automatic Serial Number Increment
|
Yes
|
|
Defective Product Parameter Range Setting
|
Yes
|
|
Centralized Control of Parameters
|
Yes
|
|
Working Hours
|
Continuous Operation
|
Equipment can work continuously for more than 24 hours
|
Equipment configuration:
4. Standard Equipment Configuration
4.1 Test Host (Including Electronic Load): 1 Unit
4.2 Light Source System (Including Optical System): 1 Set
4.3 Industrial Computer: 1 Unit
4.4 High-Speed Data Acquisition A/D Board: 1 Piece
4.5 Specialized Measurement Software: 1 Set
4.6 Standard Solar Module (For Irradiance Correction, Compensation, and Uniformity Measurement): 1 Unit